Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
 

About This Item

 

Full Description

The amount of heat flux passing through the building envelope directly affects the energy use for the thermal conditioning of the building. The ventilatedcavity behind the traditional external claddings (e.g., vinyl siding, brick veneer) adjacent to the wall core can contribute to the magnitude of the heat fluxentering or leaving the indoor space. Thus, the effect of the ventilated air-spaces on the variation of the heat flux passing the wall core is investigated in thisstudy. A numerical code is developed for the steady-state condition and verified with available in the literature hot box tests. Several simulations areperformed, and the effects of the air change rate in the air gap (0 to 1000 1/h), seasonal variation (summer and winter conditions), and external claddingtype (brick and vinyl siding) on the heat flux passing through the wall core are discussed. The results show that the ventilated air-spaces have an impact onthe thermal performance of the entire assembly.