Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $179.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

This standard describes a procedure for determining shop or field conformance to a specified coating dry film thickness (DFT) range on ferrous and non-ferrous metal substrates using nondestructive coating thickness gages (magnetic and electronic) described in ASTM D 7091.

The procedures for adjustment and measurement acquisition for two types of gages: "magnetic pull-off" (Type 1) and "electronic" (Type 2) are described in ASTM D 7091.

This standard defines a procedure to determine whether dry coatings conform to the minimum and the maximum thickness specified. See Note 11.1 for an example of a possible modification when measuring dry film thickness on overcoated surfaces.

This document is not intended to prescribe a frequency of coating thickness measurement for a coating failure investigation.
 

Document History

  1. SSPC PA 2


    Procedure for Determining Conformance to Dry Coating Thickness Requirements

    • Most Recent
  2. SSPC PA 2


    Procedure for Determining Conformance to Dry Coating Thickness Requirements

    • Historical Version
  3. SSPC PA 2


    Procedure for Determining Conformance to Dry Coating Thickness Requirements, Includes Editorial Revision (2018)

    • Historical Version
  4. SSPC PA 2

    👀 currently
    viewing


    Procedure for Determining Conformance to Dry Coating Thickness Requirements

    • Historical Version
  5. SSPC PA 2


    Procedure for Determining Conformance to Dry Coating Thickness Requirements

    • Historical Version
  6. SSPC PA 2


    Measurement of Dry Coating Thickness with Magnetic Gages (Includes 2009 Revisions)

    • Historical Version