Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
 

About This Item

 

Full Description

Latent loads on cooling equipment are usually approximated by assuming a constant indoor relative humidity. This fails to account for the variations in latent loads that result from weather, occupancy, and ventilation characteristics . To properly address this issue, it is necessary to estimate the conditions of interior humidity under which the equipment operates.

To simulate time-dependent interior humidity, a moisture mass balance is applied to the control volume of the envelope of a residential structure. Moisture transport mechanisms incorporated include: infiltration, cooling coil condensation, internal generation from occupants, sorption from hygroscopic building materials, reevaporation of condensate, and air-to-air heat exchangers. Equations and computer algorithms are presented. Comparisons of model predictions and experimental data demonstrate acceptable accuracy.

Details are given on the application of the model in generating a regression equation that calculates seasonal performance factors (SPF) for cooling equipment. Inputs to the equation are: infiltration characteristics of the structure, summer humidity ratio hours, thermostat set point, and equipment EER. A data base of humidity ratio hours generated from TRY weather tapes is presented. Plots of SPF show strong variation with summer humidity ratio hours.