Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $1,113.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

IEC 61008-1:2010+A1:2012+A2:2013 applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. This third edition cancels and replaces the second edition published in 1996, amendment 1 (2002) and amendment 2 (2006). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- complete revision of EMC sequences, including the new test T.2.6 already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 1 and 2;
- revision of test procedure for IΔn< /sub> between 5 A and 200 A;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- tests for the use of RCCBs in IT systems.
This consolidated version consists of the third edition (2010), its amendment 1 (2012) and its amendment 2 (2013). Therefore, no need to order amendments in addition to this publication.
 

Document History

  1. IEC 61008-1 Ed. 3.2 b:2013

    👀 currently
    viewing


    Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules CONSOLIDATED EDITION

    • Most Recent
  2. IEC 61008-1 Amd.2 Ed. 3.0 b:2013


    Amendment 2 - Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

    • Historical Version
  3. IEC 61008-1 Ed. 3.1 b:2012


    Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules CONSOLIDATED EDITION

    • Historical Version
  4. IEC 61009-1 Ed. 3.1 b:2012


    Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules CONSOLIDATED EDITION

    • Historical Version
  5. IEC 61008-1 Amd.1 Ed. 3.0 b:2012


    Amendment 1 - Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

    • Historical Version
  6. IEC 61008-1 Ed. 3.0 b:2010


    Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

    • Historical Version
  7. IEC 61008-1 Ed. 2.2 b:2006


    Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules CONSOLIDATED EDITION

    • Historical Version
  8. IEC 61009-1 Ed. 2.1 b:2003


    Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules CONSOLIDATED EDITION

    • Historical Version