Language:
    • Available Formats
    •  
    • Availability
    • Priced From ( in USD )
    • Secure PDF 🔒
    • Immediate download
    • $152.00
    • Add to Cart
    • Printed Edition
    • Ships in 1-2 business days
    • $152.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations.

This standard applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz a.c. networks.

It does not apply to electrical and electronic equipment for connection to 400 Hz a.c. networks. Tests for these networks will be covered by future IEC standards.

The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations.
 

Document History

  1. CAN/CSA-CEI/IEC 61000-4-11:22


    Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase

    • Most Recent
  2. CAN/CSA-CEI/IEC 61000-4-11:19


    Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests (Adopted IEC 61000-4-11:2004, edition 2:2004, consolidated with amendment 1:2017)

    • Historical Version
  3. CAN/CSA-CEI/IEC 61000-4-11-05 (R2018)

    👀 currently
    viewing


    Electromagnetic Compatibility (EMC) - Part 4-11: Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests (Adopted CEI/IEC 61000-4-11:2004, second edition, 2004-03)

    • Historical Version