About This Item

 

Full Description

BS EN 60332-1-2:2004+A11:2016 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.

NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required. Recommended requirements for performance are given in Annex A.


IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended.

NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)


Cross References:
IEC 60332-1-1
IEC 60695-4
IEC Guide 104
EN 60332-1-1:2004
EN 60695-4:1995
IEC 60332-1-3
IEC 60332-2-2
IEC 60332-3
IEC 60811-203
ISO 13943


Incorporates the following:
Amendment, November 2015. Amends and replaces BS EN 60332-1-2:2004 which remains current. Amendment, August 2016. Amends and replaces BS EN 60332-1-2:2004+A1:2015 which remains current
 

Document History

  1. BS EN 60332-1-2:2004+A12:2020


    Tests on electric and optical fibre cables under fire conditions-Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

    • Most Recent
  2. BS EN 60332-1-2:2004+A11:2016

    👀 currently
    viewing


    Tests on electric and optical fibre cables under fire conditions-Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

    • Historical Version
  3. BS EN 60332-1-2:2004+A1:2015


    Tests on electric and optical fibre cables under fire conditions-Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

    • Historical Version
  4. BS EN 60332-1-2:2004


    Tests on electric and optical fibre cables under fire conditions. Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

    • Historical Version
  5. BS EN 50265-2-1:1999


    Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures-1 kW pre-mixed flame-1 kW pre-mixed flame

    • Historical Version
  6. BS 4066-1:1980


    Tests on electric cables under fire conditions-Method of test on a single vertical insulated wire or cable

    • Historical Version