BS EN 1090-5:2017 specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.

Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.

Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in lowstress areas.

This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.

A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.

Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.

NOTE The structures covered in this standard can be for example
  • single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;
  • single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or
  • suspended ceilings for interior fitting.

Cross References:
EN 508-2
EN 1090-1
EN 1090-3
CEN/TS 1187
EN 1995-1
EN 1999-1-1
EN 1999-1-4
EN 10204
EN 13501-5
EN 62305-3:2011
IEC 62305-3:2010
EN ISO 376
ISO 376
EN ISO 717-1
ISO 717-1
EN ISO 11654
ISO 11654
EN 1396
EN 1990
EN 1991-1-1
EN 1991-1-2
EN 1991-1-3
EN 1991-1-4
EN 1991-1-5
EN 1991-1-6
EN 1991-1-7
EN 1992
EN 1993-1-3
EN 1993-1-4
EN 1993-1-5
EN 1996
EN 1998-1
EN ISO 2081
ISO 2081
EN ISO 2409
ISO 2409
EN ISO 2808
ISO 2808
EN ISO 3506-1
ISO 3506-1
EN ISO 3506-2
ISO 3506-2
EN ISO 3506-3
ISO 3506-3
EN ISO 3506-4
ISO 3506-4
EN ISO 4042
ISO 4042
EN ISO 6270-1
ISO 6270-1
EN ISO 9227
ISO 9227
EN 10143
EN 10152
EN 10162
EN 12056-1
EN 12056-3
EN ISO 12944-1
ISO 12944-1
EN ISO 12944-2
ISO 12944-2
EN ISO 12944-4
ISO 12944-4
EN ISO 12944-6
ISO 12944-6
EN ISO 12944-7
ISO 12944-7
EN 13523-1
EN 13523-6
EN 13523-7
EN 13523-8
EN ISO 14713-1
ISO 14713-1
EN 14783
EN ISO 17872
ISO 17872
ASTM D5796
EN 1090-4
EN 1993-1-1
EN 1999-1-2
EN 14782
EN ISO 354
ISO 354


All current amendments available at time of purchase are included with the purchase of this document.