Full Description

Scope

This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applications, and their requirements are not completely covered by this standard. This standard is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Purpose

Capabilities required of ac high voltage circuit breakers intended to protect generator circuits, may be very different from the capabilities required for standard high voltage circuit breakers, intended for service protecting standard distribution circuits which are specified in other industry standards. [Here we refer to C37.04, C37.06 , C37.09, and C37.010 as well as IEC 62271-100.] The purpose of this document is to provide standard requirements, tests and application guidelines for ac high-voltage generator circuit breakers.

Abstract

Revision Standard - Superseded. Supersedes IEEE C37.013-1997, and IEC/IEEE 62271-37-013-2015/Cor1-2017.
 

Document History

  1. IEEE/IEC 62271-37-013-2021


    IEEE/IEC International Standard for High-voltage switchgear and controlgear--Part 37-013: Alternating current generator circuit-breakers

    • Most Recent
  2. IEEE/IEC 62271-37-013-2015

    👀currently
    viewing


    IEEE/IEC International Standard for High-voltage switchgear and controlgear -- Part 37-013: Alternating-current generator circuit-breakers

    • Historical Version
  3. IEEE C37.013-1997


    IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis

    • Historical Version
  4. IEEE C37.013-1993


    IEEE Standard for AC High Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis

    • Historical Version
  5. IEEE C37.013-1989


    IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. IEEE/IEC 62271-37-013-2015/Cor 1-2017

    Free
    Download


    IEEE/IEC International Standard for high-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers: Corrigendum 1