Scope

This guide establishes methods by which equipment may be tested for resistance to the effects of arcing due to an internal fault. Equipment types covered in this guide include metal-enclosed switchgear as defined by ANSI/IEEE C37.20.1TM, C37.20.2TM and C37.20.3TM; metal-enclosed bus as defined by ANSI/IEEE C37.23 TM; medium-voltage ac controllers as defined by UL 347: motor control centers as defined by UL 845; and switchboards as defined by UL 891. This guide applies only to equipment utilizing air as the primary insulating medium and rated 38 kV ac or below. It applies to both indoor and outdoor equipment; however, special consideration must be given to the building size and construction for indoor applications (not fully addressed by this document).The tests and assessments described in this guide are only applicable to arcing faults occurring entirely in air within the enclosure when doors and covers are properly secured in accordance with the rated Accessibility Type. This guide does not apply to arcing faults that occur within components of the equipment, such as instrument transformers, sealed interrupting devices, fuses, and so on.Designs that meet the requirements of this guide are referred to as arc-resistant.

Abstract

Revision Standard - Inactive - Superseded. A procedure for testing and evaluating the performance of switchgear for internal arcing faults is covered. A method of identifying the capabilities of this equipment is given. Service conditions, installation, and application of equipment are also discussed. As used in this document, the term "switchgear" is used as a general term covering switching and interrupting devices and their combination with associated control, instrumentation, metering, protective and regulating devices, assemblies of those devices with associated interconnections, accessories, and supporting structures used primarily in conjunction with the generation, transmission, distribution, and conversion of electrical power.
 

Document History

  1. IEEE C37.20.7

    👀 currently
    viewing


    IEEE Draft Guide for Testing Switchgear Rated 52 kV for Internal Arcing Faults

    • Most Recent
  2. IEEE C37.20.7-2007


    IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults

    • Historical Version
  3. IEEE C37.20.7-2001


    IEEE Guide for Testing Medium-Voltage Metal-Enclosed Switchgear for Internal Arcing Faults

    • Historical Version