Scope

This standard covers the following types and preferred ratings for enclosed low-voltage ac power circuit breakers: a) Stationary or drawout type of two-, three-, or four-pole construction with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V respectively b) Unfused or fused type c) Manually operated or power operated, with or without a trip system d) Fused drawout assemblies consisting of current-limiting fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a nonintegrally fused circuit breaker; In this standard, the term circuit breaker shall mean enclosed low-voltage ac power circuit breaker, either fused or unfused. The term unfused circuit breaker shall mean a circuit breaker without either integrally or nonintegrally mounted fuses, and the term fused circuit breaker shall mean a circuit breaker incorporating current-limiting fuses, whether integrally mounted or nonintegrally mounted.

Purpose

This standard a) Establishes minimal functional requirements b) Establishes preferred rating structure c) Provides preferred ratings

Abstract

Revision Standard - Active. The following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.
 

Document History

  1. IEEE C37.13-2015

    👀 currently
    viewing


    IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

    • Most Recent
  2. IEEE C37.13-2008


    IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

    • Historical Version
  3. IEEE C37.13-1990


    IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

    • Historical Version
  4. IEEE C37.13-1981


    IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

    • Historical Version
  5. IEEE/ANSI C37.13-1973


    American National Standard for Low-Voltage AC power Circuit Breakers used in Enclosures

    • Historical Version