Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $278.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant. Provides formulae for current ratings and losses. The formulae given are essentially literal and designedly leave open the selection of certain important parameters. These may be divided into three groups: - parameters related to construction of a cable (for example, thermal resistivity of insulating material) for which representative values have been selected based on published work; - parameters related to the surrounding conditions, which may vary widely, the selection of which depends on the country in which the cables are used or are to be used; - parameters which result from an agreement between manufacturer and user and which involve a margin for security of service (for example, maximum conductor temperature).
 

Document History

  1. IEC 60287-1-1 Ed. 3.0 en:2023


    Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General

    • Most Recent
  2. IEC 60287-1-1 Ed. 2.1 b:2014


    Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General CONSOLIDATED EDITION

    • Historical Version
  3. IEC 60287-1-1 Ed. 2.0 b:2006

    👀currently
    viewing


    Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General

    • Historical Version
  4. IEC 60287-1-1 Ed. 1.2 b:2001


    Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General CONSOLIDATED EDITION

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. IEC 60287-1-1 Amd.1 Ed. 2.0 b:2014


    Amendment 1 - Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General