Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $734.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

CISPR 11:2015+A1:2016+A2:2019 applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy. This standard covers emission requirements related to radio-frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6. For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.13), this standard covers emission requirements related to radio-frequency disturbances in the frequency range of 9 kHz to 18 GHz. Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard. Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard. This sixth edition cancels and replaces the fifth edition published in 2009 and its Amendment 1 published in 2010. It constitutes a technical revision. It introduces and permits type testing on components of power electronic equipment, systems and installations. Its emission limits apply now to low voltage (LV) a.c. and d.c. power ports, irrespective of the direction of power transmission. Several limits were adapted to the practical test conditions found at test sites. They are also applicable now to power electronic ISM RF equipment used for wireless power transfer (WPT), for instant power supply and charging purposes. The limits in the range 1 GHz to 18 GHz apply now to CW-type disturbances and to fluctuating disturbances in a similar, uniform and technology-neutral way. For these measurements, two alternative methods of measurement are available, the traditional log-AV method and the new APD method. It has the status of a Product Family EMC standard in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications (2014). This consolidated version consists of the sixth edition (2015), its amendment 1 (2016) and its amendment 2 (2019). Therefore, no need to order amendment in addition to this publication.
 

Document History

  1. CISPR 11 Ed. 7.0 b:2024


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

    • Most Recent
  2. CISPR 11 Ed. 6.2 b:2019

    👀currently
    viewing


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement CONSOLIDATED EDITION

    • Historical Version
  3. CISPR 11 Ed. 6.1 b:2016


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement CONSOLIDATED EDITION

    • Historical Version
  4. CISPR 11 Ed. 6.0 b:2015


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

    • Historical Version
  5. CISPR 11 Ed. 5.1 b:2010


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement CONSOLIDATED EDITION

    • Historical Version
  6. CISPR 11 Ed. 5.0 b:2009


    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

    • Historical Version
  7. CISPR 11 Ed. 4.1 b:2004


    Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement CONSOLIDATED EDITION

    • Historical Version