Language:
-
- Available Formats
- Availability
- Priced From ( in USD )
-
-
Secure PDF
Secure PDF Files
Secure PDF files include digital rights management (DRM) software. DRM is included at the request of the publisher, as it helps them protect their copyright by restricting file sharing. In order to read a Secure PDF, you will need to install the FileOpen Plug-In on your computer. The FileOpen Plug-In works with Adobe Reader and other viewers. Visit FileOpen to see the full list.
-
What you can do with a Secure PDF:
- Print
- Search
- Highlight
- Bookmark
- Immediate download
- $121.00
- Add to Cart
-
Secure PDF
-
- Printed Edition
- Ships in 1-2 business days
- $121.00
- Add to Cart
Customers Who Bought This Also Bought
-
CAN/CSA E335-2-4-94 (R2005)
Priced From $68.00 -
CAN/CSA Z243.177.3-91 (R2000)
Priced From $132.00 -
CAN/CSA-ISO/IEC 8823-2-97 (R2001)
Priced From $68.00 -
CAN/CSA-ISO/IEC 9594-5:21
Priced From $212.00
About This Item
Full Description
1.1
Scope
ISO 9918 is one of a series of International Standards based on IEC 601-1; in IEC 601-1 (the ""General Standard""), this type of International Standard is referred to as a ""Particular Standard"". As stated in 1.3 of IEC 601-1:1988, the requirements of this International Standard take precedence over those of IEC 601-1.
The scope and object given in clause 1 of IEC 601-1:1988 apply except that 1.1 shall be replaced by the following:
This International Standard specifies requirements for the safety of capnometers, as defined in 1.3.6.
It applies to capnometers used with adults, children, and neonat es. It does not apply to devices intended for use as transcutaneous monitors.
Capnometers intended for use in laboratory research applications are outside the scope of this International Standard.
Scope
ISO 9918 is one of a series of International Standards based on IEC 601-1; in IEC 601-1 (the ""General Standard""), this type of International Standard is referred to as a ""Particular Standard"". As stated in 1.3 of IEC 601-1:1988, the requirements of this International Standard take precedence over those of IEC 601-1.
The scope and object given in clause 1 of IEC 601-1:1988 apply except that 1.1 shall be replaced by the following:
This International Standard specifies requirements for the safety of capnometers, as defined in 1.3.6.
It applies to capnometers used with adults, children, and neonat es. It does not apply to devices intended for use as transcutaneous monitors.
Capnometers intended for use in laboratory research applications are outside the scope of this International Standard.