About This Item

 

Full Description

BS ISO 11929-1:2019 specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the coverage interval" for a non-negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, the measurand can be the net count rate as the difference of the gross count rate and the background count rate, or the net activity of a sample. It can also be influenced by calibration of the measuring system, by sample treatment and by other factors.

Cross References:
ISO/IEC Guide 99
JCGM 101:2008
ISO 80000-1
ISO/IEC Guide 98-3
JCGM 200:2012
ISO 3534-1
JCGM 102:2011
ISO/IEC Guide 98-3-2
ISO/IEC Guide 98-3-1
ISO 80000-10
JCGM 100:2008
JCGM 106:2012
ISO 11665 (all parts)
ISO 28218
ISO 9696
ISO 18589 (all parts)
ISO 9697
JCGM 104:2009
ISO 10703
ISO 7503 (all parts)
ISO/IEC 80000-2:2009
ISO 9698
IEC/TR 62461
ISO/IEC Guide 98-4:2012
ISO/IEC Guide 98-1:2009


All current amendments available at time of purchase are included with the purchase of this document.
 

Document History

  1. BS ISO 11929-1:2019

    👀 currently
    viewing


    Determination of the characteristic limits (decision threshold, detection limit and limits of the coverage interval) for measurements of ionizing radiation. Fundamentals and application-Elementary applications

    • Most Recent
  2. BS ISO 11929:2010


    Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation. Fundamentals and application

    • Historical Version
  3. BS 08/30166519 DC


    BS ISO 11929. Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation. Fundamentals and application

    • Historical Version
  4. BS ISO 11929-5:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and applications to counting measurements on filters during accumulation of radioactive material

    • Historical Version
  5. BS ISO 11929-6:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and applications to measurements by use of transient mode

    • Historical Version
  6. BS ISO 11929-8:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and application to unfolding of spectrometric measurements without the influence of sample treatment

    • Historical Version
  7. BS ISO 11929-7:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and general applications

    • Historical Version
  8. BS ISO 11929-1:2000


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and application to counting measurements without the influence of sample treatment

    • Historical Version
  9. BS ISO 11929-2:2000


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and application to counting measurements with the influence of sample treatment

    • Historical Version
  10. BS ISO 11929-3:2000


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment

    • Historical Version
  11. BS ISO 11929-4:2001


    Determination of the detection limit and decision threshold for ionizing radiation measurements-Fundamentals and application to measurements by use of linear-scale analogue ratemeters, without the influence of sample treatment

    • Historical Version