Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Secure PDF 🔒
    • 👥
    • Immediate download
    • $190.50
    • Add to Cart
    • Printed Edition
    • Ships in 1-2 business days
    • $190.50
    • Add to Cart
    • Printed Edition + PDF
    • Immediate download
    • $257.81
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

BS EN 61000-6-2:2005 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in industrial environments, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.

This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.

BS EN 61000-6-2:2005 applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations.

The environments encompassed by this standard are industrial, both indoor and outdoor. Industrial locations are in addition characterised by the existence of one or more of the following:

- industrial, scientific and medical (ISM) apparatus (as defined in CISPR 11);

- heavy inductive or capacitive loads are frequently switched;

- currents and associated magnetic fields are high.

The object of BS EN 61000-6-2:2005 is to define immunity test requirements for apparatus defined inthe scope in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.

The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard, but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.

NOTE 1 Information on other disturbance phenomena is given in IEC 61000-4-1. Test requirements are specified for each port considered.

NOTE 2 Safety considerations are not covered by this standard.

NOTE 3 In special cases, situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where an apparatus is installed in proximity to ISM equipment as defined in CISPR 11 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances, special mitigation measures may have to be employed.

NOTE 4 The industrial environment may be changed by special mitigation measures. Where such measures can be shown to produce an electromagnetic environment equivalent to the residential, commercial or light-industrial environment, then the generic standard for this environment, or the relevant product standard, should be applied.



Cross References:
IEC 60050-161
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CISPR 22
EN 61000-4-2:1995
EN 61000-4-3:2002
EN 61000-4-4:2004
EN 61000-4-5:1995
EN 61000-4-8:1993
EN 61000-4-11:2004
EN 55022
IEC 61000-4-1
IEC 61000-4-20
CISPR 11
89/336/EEC
1999/5/EC
 

Document History

  1. BS EN IEC 61000-6-2:2019


    Electromagnetic compatibility (EMC)-Generic standards. Immunity standard for industrial environments

    • Most Recent
  2. BS EN 61000-6-2:2001


    Electromagnetic compatibility (EMC)-Generic standards. Immunity for industrial environments

    • Historical Version
  3. BS EN 61000-6-2:2005

    👀currently
    viewing


    Electromagnetic compatibility (EMC)-Generic standards-Immunity for industrial environments

    • Historical Version
  4. BS EN 61779-2:2000


    Electrical apparatus for the detection and measurement of flammable gases-Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in the air

    • Historical Version
  5. BS EN 61000-6-2:1999


    Electromagnetic compatibility (EMC). Generic standards-Immunity for industrial environments-Generic immunity standard for industrial environments

    • Historical Version
  6. BS EN 50055:1999


    Electrical apparatus for the detection and measurement of combustible gases. Performance requirements for Group I apparatus indicating up to 5 % (V/V) methane in air

    • Historical Version
  7. BS EN 50082-2:1995


    Electromagnetic compatibility. Generic immunity standard-Industrial environment

    • Historical Version
  8. BS EN 50055:1991


    Electrical apparatus for the detection and measurement of combustible gases. Performance requirements for Group I apparatus indicating up to 5 % (V/V) methane in air

    • Historical Version
  9. BS 6020-2:1981


    Instruments for the detection of combustible gases-Specification for safety and performance requirements for Group I instruments reading up to 5% methane in air

    • Historical Version