1.1 This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus.
Note 1: The precisions for fire point were not determined in the current interlaboratory program. Fire point is a parameter that is not commonly specified, although in some cases, knowledge of this flammability temperature may be desired.
1.2 This test method is applicable to all petroleum products with flash points above 79 °C (175 °F) and below 400 °C (752 °F) except fuel oils.
Note 2: This test method may occasionally be specified for the determination of the fire point of a fuel oil. For the determination of the flash points of fuel oils, use Test Method D93. Test Method D93 should also be used when it is desired to determine the possible presence of small but significant concentrations of lower flash point substances that may escape detection by Test Method D92. Test Method D1310 can be employed if the flash point is known to be below 79 °C (175 °F).
1.3 The values stated in SI units are to be regarded as the standard.
1.3.1 Exception-The values given in parentheses are for information only.
1.4 WARNING-Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use Caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 11.1.3, and 11.2.4.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Document History
-
ASTM D92-18
currently
viewing
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Most Recent
-
ASTM D92-16b
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-16a
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-16
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-12b
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-12a
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-12
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-11
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-05a(2010)
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-05a
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-05
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-02b
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-02a
Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester- Historical Version
-
ASTM D92-02
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version
-
ASTM D92-01
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version
-
ASTM D92-98a
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version
-
ASTM D92-97
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version
-
ASTM D92-92
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version
-
ASTM D92-85
Standard Test Method for Flash and Fire Points by Cleveland Open Cup- Historical Version