1.1 This test method describes the determination of the flash point and fire point of petroleum products by a manual Cleveland open cup apparatus or an automated Cleveland open cup apparatus.

Note 1 - The precisions for fire point were not determined in the current interlaboratory program. Fire point is a parameter that is not commonly specified, although in some cases, knowledge of this flammability temperature may be desired.

1.2 This test method is applicable to all petroleum products with flash points above 79°C (175°F) and below 400°C (752°F) except fuel oils.

Note 2 - This test method may occasionally be specified for the determination of the fire point of a fuel oil. For the determination of the flash points of fuel oils, use Test Method D93. Test Method D93 should also be used when it is desired to determine the possible presence of small, but significant, concentrations of lower flash point substances that may escape detection by Test Method D92. Test Method D1310 can be employed if the flash point is known to be below 79°C (175°F).

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 WARNING-Mercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA's website-http://www.epa.gov/mercury/faq.htm-for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 11.1.3, and 11.2.4.

 

Document History

  1. ASTM D92-18


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Most Recent
  2. ASTM D92-16b


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  3. ASTM D92-16a


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  4. ASTM D92-16


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  5. ASTM D92-12b


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  6. ASTM D92-12a


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  7. ASTM D92-12

    👀currently
    viewing


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  8. ASTM D92-11


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  9. ASTM D92-05a(2010)


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  10. ASTM D92-05a


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  11. ASTM D92-05


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  12. ASTM D92-02b


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  13. ASTM D92-02a


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

    • Historical Version
  14. ASTM D92-02


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version
  15. ASTM D92-01


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version
  16. ASTM D92-98a


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version
  17. ASTM D92-97


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version
  18. ASTM D92-92


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version
  19. ASTM D92-85


    Standard Test Method for Flash and Fire Points by Cleveland Open Cup

    • Historical Version