1.1 This test method covers the determination of whether a liquid complies with the closed-cup flash point requirements in government regulations, or in specifications, or as agreed between the purchaser and the seller.

1.2 This test method is limited to a temperature range between 0 and 110°C (32 and 230°F).

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 Warning-Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.

1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM D3934-20

    👀 currently
    viewing


    Standard Test Method for Flash/No Flash Test-Equilibrium Method by a Closed-Cup Apparatus

    • Most Recent
  2. ASTM D3934-14


    Standard Test Method for Flash/No Flash Test--Equilibrium Method by a Closed-Cup Apparatus

    • Historical Version
  3. ASTM D3934-90(2007)


    Standard Test Method for Flash/No Flash Test-Equilibrium Method by a Closed-Cup Apparatus

    • Historical Version
  4. ASTM D3934-90(1996)e1


    Standard Test Method for Flash/No Flash Test - ;Equilibrium Method by a Closed-Cup Apparatus

    • Historical Version
  5. ASTM D3934-90(2001)


    Standard Test Method for Flash/No Flash Test - ;Equilibrium Method by a Closed-Cup Apparatus

    • Historical Version