-
- Available Formats
- Options
- Availability
- Priced From ( in USD )
-
- Immediate download
- $133.00
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
- $133.00
- Add to Cart
-
- Printed Edition + PDF
- Immediate download
- $193.00
- Add to Cart
Customers Who Bought This Also Bought
-
ASHRAE 195-2013
Priced From $71.00 -
ASHRAE 145.2-2016
Priced From $83.00 -
ASHRAE 218-2019
Priced From $71.00 -
ASHRAE 37-2009 (RA 2019)
Priced From $71.00
About This Item
Full Description
Standard 62.2 is the consensus ventilation and indoor air quality (IAQ) standard for dwelling units in residential occupancies in which the occupants are nontransient. The standard describes the minimum requirements to achieve acceptable IAQ via dwelling-unit ventilation, local mechanical exhaust, and source control.
Dwelling-unit ventilation is intended to dilute the unavoidable contaminant emissions from people, materials, and background processes. Local mechanical exhaust is intended to remove contaminants from locations such as kitchens and bathrooms that, because of their design function, are expected to contain sources of contaminants.
The standard includes secondary requirements that focus on properties and performance of residential ventilation systems. Examples include sound and airflow ratings for fans, controls, and labeling requirements. The standard provides additional compliance pathways for existing dwellings.
Significant changes in the 2022 edition include improvements to organize and clarify existing provisions, an increase in the stringency of compartmentalization requirements for attached dwelling units, and a requirement for supply or balanced dwelling-unit mechanical ventilation systems for attached dwelling units on enclosed corridors.
Document History
-
ASHRAE 62.2-2022
currently
viewing
Standard 62.2-2022 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings (ANSI Approved)- Most Recent
-
ASHRAE 62.2-2019 -
Standard 62.2-2019 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings- (ANSI Approved)- Historical Version
-
ASHRAE 62.2-2016
Standard 62.2-2016 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings (ANSI Approved)- Historical Version
-
ASHRAE 62.2-2013
Standard 62.2-2013 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)- Historical Version
-
ASHRAE 62.2-2010
Standard 62.2-2010 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)- Historical Version
-
ASHRAE 62.2-2007
Standard 62.2-2007 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)- Historical Version
-
ASHRAE 62.2-2004
Standard 62.2-2004 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI Approved)- Historical Version
-
ASHRAE 62.2-2003
Standard 62.2-2003 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings- Historical Version