About This Item

 

Full Description

Specifies the immunity requirements, test methods and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. Establishes a common reference for evaluating the performance of equipment when subjected to high-energy disturbances on the power and interconnection lines. The Standard is one of a series of Standards applicable to electromagnetic compatibility. This Standard is identical with and has been reproduced from IEC 61000-4-5:1995 and IEC 61000-4-5:1995/Corrig. 1:1995.
 

Document History

  1. AS IEC 61000.4.5:2017


    Electromagnetic compatibility (EMC), Part 4.5: Testing and measurement techniques - Surge immunity test

    • Most Recent
  2. AS/NZS 61000.4.5:2006


    Electromagnetic compatibility (EMC), Part 4.5: Testing and measurement techniques - Surge immunity test

    • Historical Version
  3. AS/NZS 61000.4.5:1999

    👀 currently
    viewing


    Electromagnetic compatibility (EMC), Part 4.5: Testing and measurement techniques - Surge immunity test

    • Historical Version