Full Description

Wide use of R-245fa is restrained by the lack of consistent data on thermophysical properties. This paper reviews thermophysical data for R-245fa available from different sources, and it is concluded that the most crucial inconsistency is between data reported by different researchers for the phase equilibrium and PVT measurements. In order to provide accurate data on properties of R-245fa, the vapor-liquid equilibrium parameters and PVT surface over a wide range of parameters relevant to commercial applications of R-245fa were measured. The information obtained, along with other reliable and verified data on thermodynamic properties of R- 245fa, was fitted with appropriate property correlation models.

Units: Dual