This item is not available for sale.

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Inverter Duty Motors

UL 1004-8

1 Scope

1.1 This Standard is intended to be read together with the Standard for Rotating Electrical Machines - General Requirements, UL 1004-1. The numbering of the Sections in this Standard corresponds to the like numbered Sections in UL 1004-1. The numbering of the paragraphs are unique to this Standard, and do not directly correspond to the like numbered paragraphs in UL 1004-1. The requirements in this Standard supplement or amend the requirements in UL 1004-1. The requirements of UL 1004-1 apply unless modified by this Standard. For Sections not shown, refer to the Standard for Rotating Electrical Machines - General Requirements, UL 1004-1.

1.2 This Standard applies to squirrel cage polyphase induction motors intended for use with variable voltage and variable frequency controls, commonly referred to as inverters. The requirements in this Standard are intended to evaluate the suitability of the motor for normal use when fed from an inverter supply through a manufacturer declared range of operating conditions.

1.3 This Standard does not address:

a) The efficacy of motor overtemperature protection under abnormal conditions;

b) The operation of a motor under unusual service conditions as described in NEMA MG-1, Standard for Motors and Generators, Part 31; nor

c) The operation of a motor in hazardous (Classified) locations.
 

Document History

  1. UL 1004-8


    Standard for Inverter Duty Motors

    • Most Recent
  2. UL 1004-8

    👀 currently
    viewing


    Standard for Inverter Duty Motors

    • Historical Version