This part of ISO 11929 specifies suitable statistical values which allow an assessment of the detection capabilities in high resolution gamma spectrometric ionizing radiation measurements, without the influence of sample treatment [1 to 11]. For this purpose, statistical methods are used to specify the following two statistical values characterizing given probabilities of error.

  • The decision threshold, which allows a decision to be made for each measurement with a given probability of error as to whether the registered pulses in a region of interest of the spectrum include a contribution by the sample (e.g. a peak of a gamma line of a nuclide in question).
  • The detection limit, which specifies the minimum sample contribution which can be detected with a given probability of error using the measuring procedure in question. This consequently allows a decision to be made to whether a measuring method defined in this part of ISO 11929 satisfies certain requirements and consequently suitable for the given purpose of measurement.
 

Document History

  1. ISO 11929-1:2019


    Determination of the characteristic limits (decision threshold, detection limit and limits of the coverage interval) for measurements of ionizing radiation - Fundamentals and application - Part 1: Elementary applications

    • Most Recent
  2. ISO 11929:2010


    Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation - Fundamentals and application

    • Historical Version
  3. ISO 11929-6:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 6: Fundamentals and applications to measurements by use of transient mode

    • Historical Version
  4. ISO 11929-5:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 5: Fundamentals and applications to counting measurements on filters during accumulation of radioactive material

    • Historical Version
  5. ISO 11929-7:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 7: Fundamentals and general applications

    • Historical Version
  6. ISO 11929-8:2005


    Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 8: Fundamentals and application to unfolding of spectrometric measurements without the influence of sample treatment

    • Historical Version
  7. ISO 11929-4:2001


    Determination of the detection limit and decision threshold for ionizing radiation measurements -- Part 4: Fundamentals and application to measurements by use of linear-scale analogue ratemeters, without the influence of sample treatment

    • Historical Version
  8. ISO 11929-1:2000


    Determination of the detection limit and decision threshold for ionizing radiation measurements -- Part 1: Fundamentals and application to counting measurements without the influence of sample treatment

    • Historical Version
  9. ISO 11929-3:2000

    👀 currently
    viewing


    Determination of the detection limit and decision threshold for ionizing radiation measurements -- Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment

    • Historical Version
  10. ISO 11929-2:2000


    Determination of the detection limit and decision threshold for ionizing radiation measurements -- Part 2: Fundamentals and application to counting measurements with the influence of sample treatment

    • Historical Version