Scope

This standard covers certain electrical, dimensional, and mechanical characteristics and safety requirements of single-phase, 60-Hz, liquid-filled, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 250 kVA and smaller with high voltages of 34 500 GrdY/19 920 V and below for operation between one phase and grounded neutral and low voltage of 480/240 V and below. These transformers are generally used for step-down purposes from an underground primary cable supply. This standard covers the connector, bushing, and terminal arrangements for radial or loop feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.

Purpose

This standard is intended to define the electrical, mechanical, dimensional, performance, and interchangeability requirements of the transformers covered under this standard and to assist in the proper selection of such equipment. These requirements will provide a more standard transformer design, which will benefit manufacturers by reducing the number of designs. Users will be provided a document, which can be used to purchase a transformer of standard design without having to develop any additional standards. This will be helpful to less experienced users. It also will promote standardization of these types of transformers.

Abstract

Revision Standard - Active. Certain electrical, dimensional, and mechanical characteristics are covered in this standard, and certain safety features of single-phase, 60-Hz, mineral-oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers are taken into consideration. These transformers are rated 250 kVA and smaller with high voltages of 34 500 GrdY/19 920 V and below and with low voltages of 480/240 V and below. These transformers are generally used for step-down purposes from an underground primary cable supply. The connector, bushing, and terminal arrangements for radial or loop feed systems are covered in this standard. The electrical and mechanical requirements of any accessory devices that may be supplied with the transformer are not covered in this standard.
 

Document History

  1. IEEE C57.12.38-2014

    👀 currently
    viewing


    IEEE Standard for Pad-Mounted-Type, Self-Cooled, Single-Phase Distribution Transformers 250 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 V and Below; Low Voltage, 480/240 V and Below

    • Most Recent
  2. IEEE C57.12.38-2009


    IEEE Standard for Pad-Mounted-Type, Self-Cooled, Single-Phase Distribution Transformers; High Voltage, 34 500 GrdY/19 920 V and Below, Low Voltage, 240/120 V; 167 kVA and Smaller

    • Historical Version
  3. IEEE C57.12.25-1990


    Requirements for Pad-Mounted Compartmental-Type Self-Cooled Single-Phase Distribution Transformers with Separable Insulated High-Voltage Connectors, High-Voltage, 34 500 Grd Y/19 920 Volts and Below; Low Voltage, 240/120; 167 kVA and Smaller

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. IEEE C57.12.38-2014/Cor 1-2016

    Free
    Download


    IEEE Standard for Pad-Mounted-Type, Self-Cooled, Single-Phase Distribution Transformers 250 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 V and Below; Low Voltage, 480/240 V and Below - Corrigendum 1: Figure 1A