This test procedure is intended to give a direct evaluation of the composite insulation system of an oil-immersed distribution transformer, tested as an integral unit. It is to be noted that the oil in which the transformer is immersed is to be considered a part of the insulation system. It is intent of the procedure to provide that each component of the insulation structure operate during the test under conditions that are, as nearly as possible, the same as those that it would encounter in service. Thus, it is intended that each component be evaluated in accordance with its actual function.

Purpose

The object of this test procedure is to establish a uniform method for investigating the effect of operating temperature on the life expectancy of oil-immersed distribution transformers. The results may be used, for example, to: 1) Provide data for selection of a limiting hottest-spot temperature for rating purposes, which will provide reasonable life expectancy under normal operating conditions 2) Provide data that may serve as the basis of a guide for loading 3) Permit the comparative evaluation of a proposed insulation system, with reference to a system that has proven to be acceptable in service

Abstract

New IEEE Standard - Superseded. The object of this test procedure is to establish a uniform method for investigating the effect of operating temperature on the life expectancy of oil-immersed distribution transformers. It is intended to give a direct evaluation of the composite insulation system of an oil-immersed distribution transformer, tested as an integral unit. It is to be noted that the oil in which the transformer is immersed is to be considered a part of the insulation system. It is the intent of the procedure to provide that each component of the insulation structure operate during the test under conditions that are, as nearly as possible, the same as those that it would encounter in service. Thus, it is intended that each component be evaluated in accordance with its actual function.
 

Document History

  1. IEEE C57.100-2022


    IEEE Standard for Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution, Power, and Regulating Transformers

    • Most Recent
  2. IEEE C57.100-2011


    IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers

    • Historical Version
  3. IEEE C57.100-1999


    IEEE Standard Test Procedure for Thermal Evaluation of Liquid-Immersed Distribution and Power Transformers

    • Historical Version
  4. IEEE C57.100-1986

    👀 currently
    viewing


    IEEE Standard Test Procedure for Thermal Evaluation of Oil-Immersed Distribution Transformers

    • Historical Version