BS EN 62220-1-1:2015 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories.

NOTE 1 While not recommended, applying this standard to determine the DQE of digital X-ray imaging devices integrated in a clinical system is not excluded as long as the requirements as set in this standard are respected.

Points of additional attention could be (for example but not exclusively) the establishment of the required RADIATION QUALITIES, minimizing influences of scattered and back-scattered radiation, accurate AIR KERMA measurements, positioning of the TEST DEVICE, presence of protective covers, removal of ANTI-SCATTER GRID.

This Part 1-1 is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for radiographic imaging such as, but not exclusively, CR systems, direct and indirect flat panel-detector based systems.

It is not recommended to use this part of IEC 62220 for digital X-RAY IMAGE INTENSIFIER-based systems.

NOTE 2 The use of this standard for X-RAY IMAGE INTENSIFER-based systems is discouraged based on the low frequency drop, vignetting and geometrical distortion present in these devices which may put severe limitations on the applicability of the measurement methods described in this standard.
This part of IEC 62220 is not applicable to:
  • DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental radiography;
  • slot scanning DIGITAL X-RAY IMAGING DEVICES;
  • COMPUTED TOMOGRAPHY;
  • devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging).
NOTE 3 The devices noted above are excluded because they contain many parameters (for instance, beam qualities, geometry, time dependence, etc.) which differ from those important for RADIOGRAPHY. Some of these techniques are treated in other parts of the IEC 62220 standards (IEC 62220-1-2 and IEC 62220-1-3).


Cross References:
IEC 60336
IEC TR 60788:2004
IEC 61267:2005
EN 60336
EN 61267:2006
ICRU Report 54:1996
ISO/IEC Guide 98-3:2008
IEC 62220-1-3:2008
IEC 62220-1-2:2007
IEC 61262-5:1994
ISO 12233:2000
ISO 15529:2010
ICRU Report 41:1986
IEC 60601-2-54
EN 62220-1-3:2008
EN 62220-1-2:2007
EN 61262-5:1994
EN 60601-2-54


Replaces BS EN 62220-1:2004 which remains current

All current amendments available at time of purchase are included with the purchase of this document.
 

Document History

  1. BS EN 62220-1-1:2015

    👀currently
    viewing


    Medical electrical equipment. Characteristics of digital x-ray imaging devices-Determination of the detective quantum efficiency. Detectors used in radiographic imaging

    • Most Recent
  2. BS 13/30247422 DC


    BS EN 62220-1-1. Medical electrical equipment. Characteristics of digital x-ray imaging devices. Part 1-1. Determination of the detective quantum efficiency. Detectors used in radiographic imaging

    • Historical Version
  3. BS EN 62220-1:2004


    Medical electrical equipment. Characteristics of digital X-ray imaging devices-Determination of the detective quantum efficiency

    • Historical Version