BS EN 61000-6-1:2007 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.

BS EN 61000-6-1:2007 is applicable if no relevant dedicated product or product-family EMC immunity standard exists.

BS EN 61000-6-1:2007 applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, lowvoltage power distribution system if this apparatus is intended to be used in the locations described below.

The environments encompassed by BS EN 61000-6-1:2007 are residential, commercial and lightindustrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included:

- residential properties, for example houses, apartments;

- retail outlets, for example shops, supermarkets;

- business premises, for example offices, banks;

- areas of public entertainment, for example cinemas, public bars, dance halls;

- outdoor locations, for example petrol stations, car parks, amusement and sports centres;

- light-industrial locations, for example workshops, laboratories, service centres.

Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial.

The object of BS EN 61000-6-1:2007 is to define the immunity test requirements for apparatus specified in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges.

The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.

NOTE 1 Information on other disturbance phenomena is given in IEC 61000-4-1. Test requirements are specified for each port considered.

NOTE 2 Safety considerations are not covered by this standard.

NOTE 3 In special cases, situations will arise where the levels of disturbances may exceed the test levels specified in this standard; for example where a hand-held transmitter is used in proximity to an apparatus. In these instances, special mitigation measures may have to be employed.



Cross References:
IEC 60050-161
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CISPR 22
EN 61000-4-2:1995
EN 61000-4-3:2006
EN 61000-4-4:2004
EN 61000-4-5:2006
EN 61000-4-8:1993
EN 61000-4-11:2004
EN 55022:2006
IEC 61000-4-1
IEC 61000-4-20
EN 61000-4-1:2000
EN 61000-4-20:2003
89/336/EEC
2004/108/EC


Replaces BS EN 61000-6-1:2001 which remains current.
 

Document History

  1. BS EN IEC 61000-6-1:2019


    Electromagnetic compatibility (EMC)-Generic standards. Immunity standard for residential, commercial and light-industrial environments

    • Most Recent
  2. BS EN 61000-6-1:2007

    👀 currently
    viewing


    Electromagnetic compatibility (EMC)-Generic standards. Immunity for residential, commercial and light-industrial environments

    • Historical Version
  3. BS EN 61000-6-1:2001


    Electromagnetic compatibility (EMC)-Generic standards. Immunity for residential, commercial and light-industrial environments

    • Historical Version
  4. BS EN 61779-1:2000


    Electrical apparatus for the detection and measurement of flammable gases-General requirements and test methods

    • Historical Version
  5. BS EN 50054:1999


    Electrical apparatus for the detection and measurement of combustible gases. General requirements and test methods

    • Historical Version
  6. BS EN 50082-1:1998


    Electromagnetic compatibility. Generic immunity standard-Residential, commercial and light industry

    • Historical Version
  7. BS EN 50082-1:1992


    Electromagnetic compatibility. Generic immunity standard-Residential, commercial and light industry

    • Historical Version
  8. BS EN 50054:1991


    Electrical apparatus for the detection and measurement of combustible gases. General requirements and test methods

    • Historical Version
  9. BS 6020-1:1981


    Instruments for the detection of combustible gases-Specification for general requirements and test methods

    • Historical Version