BS EN 50588-1:2015+A1:2016 covers medium power transformers. 'Medium power transformer' means a power transformer with a highest voltage for equipment higher than 1,1 kV, but not exceeding 36 kV and a rated power equal to or higher than 5 kVA but lower than 40 MVA.

National practices may require the use of highest voltages for equipment up to (but not including) 52 kV, when the rated voltage is less than 36 kV (such as Um = 38,5 kV or Um = 40,5 kV). This is considered to be an unusual case of a large power transformer, where the requirements are those for a medium power transformer with Um = 36 kV.

NOTE 1 'Large power transformer' means a power transformer with a highest voltage for equipment exceeding 36 kV and a rated power equal or higher than 5 kVA, or a rated power equal to or higher than 40 MVA regardless of the highest voltage for equipment. Large power transformers are in the scope of EN 50629.

NOTE 2 Transformers with tap changer (DETC or OLTC) are included in this European Standard even if they have separate tapping winding.

The object of this European Standard is to set up requirements related to electrical characteristics and design of medium power transformers.

The following transformers are excluded from this European Standard:
  • instrument transformers, specifically designed to supply measuring instruments, meters, relays and other similar apparatus;
  • transformers with low-voltage windings specifically designed for use with rectifiers to provide a DC supply;
  • transformers specifically designed to be directly connected to a furnace;
  • transformers specifically designed for offshore applications and floating offshore applications;
  • transformers specially designed for emergency installations;
  • transformers and auto-transformers specifically designed for railway feeding systems;
  • earthing or grounding transformers, this is, three-phase transformers intended to provide a neutral point for system grounding purposes;
  • traction transformers mounted on rolling stock, this is, transformers connected to an AC or DC contact line, directly or through a converter, used in fixed installations of railway applications;
  • starting transformers, specifically designed for starting three-phase induction motors so as to eliminate supply voltage dips;
  • testing transformers, specifically designed to be used in a circuit to produce a specific voltage or current for the purpose of testing electrical equipment;
  • welding transformers, specifically designed for use in arc welding equipment or resistance welding equipment;
  • transformers specifically designed for explosion-proof and underground mining applications,
  • transformers specifically designed for deep water (submerged) applications;
  • medium Voltage (MV) to Medium Voltage (MV) interface transformers up to 5 MVA;
  • large power transformers where it is demonstrated that for a particular application, technically feasible alternatives are not available to meet the minimum efficiency requirements set out by the commission regulation (EU) No 548/2014;
  • large power transformers which are like for like replacements in the same physical location/installation for existing large power transformers, where this replacement cannot be achieved without entailing disproportionate costs associated to their transportation and/or installation.

Cross References:
EN 50180
EN 50181
EN 50216
EN 50386
EN 50387
EN 50464-4
EN 60076
IEC 60076
EN 60076-19
IEC/TS 60076-19
EN 60085
EN 60505
IEC 60505
EN 61100
IEC 61100
IEC/TR 60616
EN 50464-1
EN 60038
IEC 60038
EN 60529
IEC 60529
EN 60721
IEC 60721
EN 62262
IEC 62262
EN ISO 9001
ISO 9001
EN ISO/IEC 17065
ISO/IEC 17065
Commission Regulation (EC) No 548/2014
2009/125/EC


All current amendments available at time of purchase are included with the purchase of this document.
 

Document History

  1. BS EN 50708-1-1:2020


    Power transformers. Additional European requirements-Common part. General requirements

    • Most Recent
  2. BS EN 50629:2015+A2:2018


    Energy performance of large power transformers (Um > 36 kV or Sr ≥ 40 MVA)

    • Historical Version
  3. BS EN 50588-1:2017


    Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV-General requirements

    • Historical Version
  4. BS EN 50588-1:2015+A1:2016

    👀 currently
    viewing


    Medium power transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV-General requirements

    • Historical Version
  5. BS EN 50629:2015+A1:2016


    Energy performance of large power transformers (Um $0G 36 kV or Sr $3M 40 MVA)

    • Historical Version
  6. BS EN 50629:2015


    Energy performance of large power transformers (Um > 36 kV or Sr > 40 MVA)

    • Historical Version
  7. BS EN 50464-1:2007+A1:2012


    Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV-General requirements

    • Historical Version
  8. BS EN 50541-1:2011


    Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV-General requirements

    • Historical Version
  9. BS EN 50464-1:2007


    Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV. General requirements

    • Historical Version
  10. BS 7844-2:1996


    Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA with highest voltage for equipment not exceeding 36 kV-Supplementary requirements for transformers with highest voltage for equipment equal to 36 kV

    • Historical Version
  11. BS 7844-1:1996


    Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA with highest voltage for equipment not exceeding 36 kV-General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV

    • Historical Version
  12. BS 7821-1:1995


    Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV-General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV

    • Historical Version
  13. BS 7821-3:1995


    Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV-Supplementary requirements for transformers with highest voltage for equipment equal to 36 kV

    • Historical Version