BS 8899:2016 gives recommendations for the improvement and maintenance of fire-fighting and evacuation provisions in existing lifts. It applies to lifts installed permanently into buildings that are either already designed for fire and rescue service use or as evacuation lifts, or intended to be modified to include such features.

This British Standard is not applicable to:
  • new lifts, whether in new buildings or existing buildings, installed after the publication of this standard;
  • lifts where the building regulations or standards for the fire safety of buildings require or recommend a lift to the level of a new fire-fighting lift, e.g. due to extension or change of use of the building;
  • double-deck lifts;
  • dual entry lifts, where the firefighters lift protected lobbies are not located consistently on the same side of the lift car on all floors served by the installation;
  • lifts with partially enclosed wells;
  • special cases such as potentially explosive atmospheres, extreme climate conditions and seismic conditions.
This British Standard covers the significant hazards, hazardous situations and events relevant to lifts for fire and rescue service use and evacuation lifts.

NOTE 1 BS EN 81-80 contains recommendations for the general improvement in safety of existing lifts relative to the base lift design standard. BS 8899 is intended to have a similar relationship with BS EN 81-72 and the evacuation lift recommendations in BS 9999.

This British Standard applies to the lift installation only. It does not give recommendations for the fire-resisting structure of the building or other elements of the building design and management.

NOTE 2 BS 9999 and BS 9991 contain recommendations related to additional building fire safety provisions needed to support the use of fire-fighting and evacuation lifts.



Cross References:
BS 476-22
BS 5655-11
BS 5655-12
BS 8486-1
BS 8486-2
BS 9999
BS EN 81-58
BS EN 81-20:2014
BS EN 81-70:2003
BS EN 81-72:2015
BS EN 81-73
BS EN ISO 14798
BS 2655-1:1970
BS 5588-5:1986
BS 5588-5:1991
BS 5588-5:2004
BS 5588-8:1988
BS 5588-8:1999
BS 5655-1
BS 5655-2
BS 5655-10
BS 5655-10.1.1
BS 5655-10.2.1
BS 5810
BS 8519
BS 9991:2011
BS 9991:2015
BS EN 81-1
BS EN 81-2
BS EN 81-72:2003
BS EN 81-80:2003
BS EN 13015
BS EN 60529:1992+A2:2013
DD CEN/TS 81-76
PAS 32-1
PAS 32-2


All current amendments available at time of purchase are included with the purchase of this document.