Full Description

For six windows the U-values measured with the MoWITT under field conditions are compared with detailed U-value computer calculations for the same conditions. Wood or aluminium frame double glazed windows with gas or air gaps were tested. There is good agreement between measurements and calculations.

KEYWORDS: windows, thermal resistance, nighttime, comparing, calculating, measuring, window frames, wood, aluminium, double glazing, laboratory testing, USA.