About This Item

 

Full Description

1.1 These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 to 360°C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus.

Note 1 - Flash point determination as above 250°C can be performed, however, the precisions have not been determined above this temperature. For residual fuels, precisions have not been determined for flash points above 100°C.

1.2 Procedure A is applicable to distillate fuels (diesel, kerosine, heating oil, turbine fuels), new lubricating oils, and other homogeneous petroleum liquids not included in the scope of Procedure B.

1.3 Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film under test conditions, or are petroleum liquids of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A.

1.4 These test methods is applicable for the detection of contamination of relatively nonvolatile or nonflammable materials with volatile or flammable materials.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

Note 2 - It has been common practice in flash point standards for many decades to alternately use a C-scale or an F-scale thermometer for temperature measurement. Although the scales are close in increments, they are not equivalent. Because the F-scale thermometer used in this procedure is graduated in 5° increments, it is not possible to read it to the 2°C equivalent increment of 3.6°F. Therefore, for the purposes of application of the procedure of the test method for the separate temperature scale thermometers, different increments must be used. In this test method, the following protocol has been adopted: When a temperature is intended to be a converted equivalent, it will appear in parentheses following the SI unit, for example 370°C (698°F). When a temperature is intended to be a rationalized unit for the alternate scale, it will appear after "or," for example, 2°C or 5°F.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.4, 7.1, 9.3, 9.4, 11.1.2, 11.1.4, 11.1.8, 11.2.2, and 12.1.2.

 

Document History

  1. ASTM D93-20


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Most Recent
  2. ASTM D93-19


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  3. ASTM D93-18


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  4. ASTM D93-16a


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  5. ASTM D93-16


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  6. ASTM D93-15a


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  7. ASTM D93-15


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  8. ASTM D93-13e1


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  9. ASTM D93-13


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  10. ASTM D93-12


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  11. ASTM D93-11


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  12. ASTM D93-10a


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  13. ASTM D93-10


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  14. ASTM D93-09


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  15. ASTM D93-08

    👀currently
    viewing


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  16. ASTM D93-07


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  17. ASTM D93-06


    Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  18. ASTM D93-02a


    Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  19. ASTM D93-02


    Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  20. ASTM D93-97


    Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester

    • Historical Version
  21. ASTM D93-94


    Standard Test Method for Flash Point by Pensky-Martens Closed Tester

    • Historical Version
  22. ASTM D93-90e1


    Standard Test Methods for Flash Point by Pensky-Martens Closed Tester

    • Historical Version
  23. ASTM D93-85


    Standard Test Method for Flash Point by Pensky-Martens Closed Tester

    • Historical Version
  24. ASTM D93-80e1


    Standard Test Methods for Flash Point By Pensky-Martens Closed Tester

    • Historical Version
  25. ASTM D93-71


    Standard Method Of Test For Flash Point By Pensky-Martens Closed Tester

    • Historical Version