1. PURPOSE
This standard defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality (IAQ) in low-rise residential buildings.

2. SCOPE
This standard applies to spaces intended for human occupancy within single-family houses and multifamily structures of three stories or fewer above grade, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails.

2.1 This standard considers chemical, physical, and biological contaminants that can affect air quality. Thermal comfort requirements are not included in this standard (see ANSI/ ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy).

2.2 While acceptable indoor air quality is the goal of this standard, it will not necessarily be achieved even if all requirements are met
a. because of the diversity of sources and contaminants in indoor air and the range of susceptibility in the population;
b. because of the many other factors that may affect occupant perception and acceptance of IAQ, such as air temperature, humidity, noise, lighting, and psychological stress;
c. if the ambient air is unacceptable and this air is brought into the building without first being cleaned (cleaning of ambient outdoor air is not required by this standard);
d. if the systems are not operated and maintained as designed; or
e. when high-polluting events occur.

2.3 This standard does not address unvented combustion space heaters.

Preview this standard!

 

Document History

  1. ASHRAE 62.2-2022


    Standard 62.2-2022 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings (ANSI Approved)

    • Most Recent
  2. ASHRAE 62.2-2019


    Standard 62.2-2019 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings- (ANSI Approved)

    • Historical Version
  3. ASHRAE 62.2-2016


    Standard 62.2-2016 -- Ventilation and Acceptable Indoor Air Quality in Residential Buildings (ANSI Approved)

    • Historical Version
  4. ASHRAE 62.2-2013


    Standard 62.2-2013 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)

    • Historical Version
  5. ASHRAE 62.2-2010


    Standard 62.2-2010 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)

    • Historical Version
  6. ASHRAE 62.2-2007

    👀 currently
    viewing


    Standard 62.2-2007 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI/ASHRAE Approved)

    • Historical Version
  7. ASHRAE 62.2-2004


    Standard 62.2-2004 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI Approved)

    • Historical Version
  8. ASHRAE 62.2-2003


    Standard 62.2-2003 -- Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. ASHRAE 62.2-2007 Addenda q and r

    Free
    Download


    Addenda q and r to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  2. ASHRAE 62.2-2007 Addenda m, n, o, p, and t

    Free
    Download


    Addenda m, n, o, p, and t to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  3. ASHRAE 62.2-2007 Addendum j

    Free
    Download


    Addendum j to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  4. ASHRAE Addenda f, g, h, i

    Free
    Download


    Addenda f, g, h, i to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  5. ASHRAE 62.2-2007 Addendum e

    Free
    Download


    Addendum e to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  6. ASHRAE 62.2-2007 Addendum d

    Free
    Download


    Addendum d to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  7. ASHRAE IC 62.2-2007-10

    Free
    Download


    Interpretation IC 62.2-2007-10 of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  8. ASHRAE IC 62.2-2007-9

    Free
    Download


    Interpretation IC 62.2-2007-9 of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

  9. ASHRAE 62.2-2007 Supplement

    Free
    Download


    Addendum a, b, c, e, and k to ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings