Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Scope

This standard describes the criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations. Figure 1 shows the boundaries of systems and equipment included in the scope of this standard. Site testing is covered in clause 7, and the boundaries for site testing are given in 1.1.2

Purpose

The purpose of this standard is to provide the principal design criteria, the design features, testing, and qualification requirements for the individual diesel-generator units that enable them to meet their functional requirements as a part of the standby power supply under the conditions produced by the design basis events cataloged in the Plant Safety Analysis

Abstract

Revision Standard - Superseded. The criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations is described.
 

Document History

  1. IEEE 387-2017


    IEEE Standard for Criteria for Diesel Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations

    • Most Recent
  2. IEEE 387-1995

    👀currently
    viewing


    IEEE Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations

    • Historical Version
  3. IEEE 387-1984


    IEEE Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations

    • Historical Version