Full Description

This code provides minimum requirements for design and construction of reinforced concrete and prestressed concrete structures for the storage and containment of refrigerated liquefied gases (RLG) with service temperatures between +40 and -325°F. The principles listed herein are applicable to concrete foundations of double-steel tanks subject to the approval of the owner.

Container design shall include the design of the container wall, its foundation (footing and floor slab), the concrete portions of its roof, and the bund wall, whenever applicable. Available in hard copy or electronic format.
 

Document History

  1. ACI CODE-376-23


    Refrigerated Liquefied Gas Containment for Concrete Structures — Code Requirements and Commentary

    • Most Recent
  2. ACI 376-11

    👀 currently
    viewing


    Code Requirements for Design & Construction of Concrete Structures for the Containment of Refrigerated Liquefied Gases & Commentary

    • Historical Version
  3. ACI 376-10


    Code Req for Design & Constr of Conc Structures for the Containment of Refrigerated Liquefied Gases & Commentary

    • Historical Version