Scope

This standard outlines a test procedure for comparing two or more insulation systems in accordance with their expected life at rated temperature. The procedure is limited to insulation systems for ac electric machines using formwound preinsulated stator coils and rated 6900 V and below. It is the intent of this procedure to evaluate insulation systems for use in usual service conditions with air cooling. It does not cover such special requirements as machines that are enclosed in gas atmospheres, or that are subjected to strong chemicals, to metal dusts, or to submersion in liquids, etc. The procedure includes instructions for testing candidate systems in comparison with known systems having a proven record of service experience and interpretation of the results.

Purpose

The purpose of this procedure is to classify insulation systems for the machinery within the scope of this standard in accordance with their temperature limits by test, rather than by chemical composition. Data from such tests may be used to establish the temperature classification of new insulation systems before they are service proven. Service-proven systems shall also be tested according to this test procedure.

Abstract

Revision Standard - Inactive-Withdrawn. A test procedure for comparing two or more insulation systems in accordance with their expected life at rated temperature is described. The procedure is limited to insulation systems for ac electric machines using form-wound preinsulated stator coils and rated 6900 V and below. This procedure is intended to evaluate insulation systems for use in usual service conditions with air cooling. It does not cover such special requirements as machines that are enclosed in gas atmospheres, or that are subjected to strong chemicals, to metal dust, or to submersion in liquids, etc. The procedure includes instructions for testing candidate systems in comparison with known systems having a proven record of service experience and interpretation of the results.
 

Document History

  1. IEEE 275-1992

    👀currently
    viewing


    IEEE Recommended Practice for Thermal Evaluation of Insulation Systems for Alternating-Current Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated 6900 V and Below

    • Most Recent
  2. IEEE 275-1981


    IEEE Recommended Practice for Thermal Evaluation of Insulation Systems for AC Electric Machinery Employing Form-Wound Pre-Insulated Stator Coils, Machines Rated 6900 V and Below

    • Historical Version
  3. IEEE 275-1966


    IEEE Proposed Test Procedure for Evaluation of Systems of Insulating Materials for A-C Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated at 50 to 2000 horsepower 35 to 1500 Kilowatts mechanical output and below 6600 volts

    • Historical Version